April 02-05, 2018
San Francisco, California

ETI0018-1615 DC/AC Power Inverter 2000 VA, 1500 Watts 12 VDC In

P/N: ETI0018-1615
DC/AC Power Inverter
2000 VA, 1500 Watts
12 VDC In

Selectable 220*/230/240 VAC Out


True sinewave output (THD < 3%)
Power On-Off Remote Control
Input & Output fully isolated
Load control cooling fan
Advanced microprocessor
Built-in transfer switch & AC circuit breaker
ROF (Remote Override Function) or ignition lockout function option
Speed up transfer time & synchronized operation with utility AC source
Input polarity reverse/ under voltage/ over voltage protections
Output short circuit/ overload/ over temperature protections
Tri-color indicators display input, output level & failure status
e-13/ CE /FCC approved
Optional 100 /110 /120 VAC Out

Rugged Universal Mount Sinewave Inverter

rear view of universal mount inverter

Model Numbers:
AC Output
AC Voltage
220 / 230 / 240 VAC
Rated Power
1500 W
Surge Power
3000 W
True sinewave (THD < 3%)
50 / 60 Hz selectable by DIP switch
AC Regulation
+/- 3%
Power Factor Allowed
COS -90° ~ COS +90°
Standard Receptacles
LED Indicator
Input voltage level, output load level & fault status
DC Input
No Load Current Draw
 1.40A  0.70A  0.40A
Stand-By Current Draw
 0.28A  0.15A  0.09A
DC Voltage
 12 VDC  24 VDC  48 VDC
Voltage Range
 10.5~15.0 VDC  21~30 VDC  42~60 VDC
Efficiency (Typ.)
 92.0%  93.0%  94.0%
 40A x 5  20A x 5  20A x 3
Circuit Breaker
10 A
Synchronous AC Transfer
Transfer Switch
25 A
Transfer Time
Inverter to utility AC:8~10 msec.: Utility AC to inverter:12~14 msec
Remote Control Unit
CR6 / CR8 optional
Low Battery Alarm
 11 VDC  22 VDC  44 VDC
Low Battery Shutdown
 10.5 VDC  21.0 VDC  42.0 VDC
Over load
Shut off output voltage, re-power on to recover
Over Voltage
 15.3 VDC  30.6 VDC  61.2 VDC
Over Temperature
Shut off output voltage, recovers automatically after temperature goes down 
Output Short
Shut off output voltage, re-power on to recover
Battery Polarity
By fuse opening
Working Temperature
0 ~ +40° C
Working Humidity
20% ~ 90% RH non-condensing
Storage Temp. Humidity
-30° C ~ +70° C / -22° F ~ +158° F / 10~95%
Safety Standards
Isolation Resistance
EMI & Radiation
Compliance to EN55022 Class A
EMS Immunity
Compliance to EN61000-3 -2, 3
Compliance to EN60950-1
Compliance to e-13 * 72/245/EEC, 95/54/EC
403 x 236 x 115 MM (L x W x H)
7.0 kgs; 2 sets / 15 kgs / CARTON
Load controlled cooling fan

Information Inquiry

Contact Us for Free Quotes or Information!

*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466