ETI0019-1003AA Portable Universal Mount DC/AC Power Inverter 500 VA, 300 Watts 24 VDC Input

ETI0018-1003AA
Portable Universal Mount DC/AC Power Inverter
500 VA, 300 Watts
24 VDC Input


100/ 110/ 120 VAC Output

Rugged Tactical Inverter

NEMA connectors on Universal Mount Inverter

ETI0018-1003AA
AC OUTPUT
Output voltage: 120 VAC True sinewave
Optional 220 VAC
Output rating: 500 VA, 300 watts continuous
Output voltage regulation: ± 3.0% static regulation of nominal
-10% to +4.0% dynamic
Overload surge capacity: 600 watts surge for 5 seconds
Output protection: Overcurrent protection
Harmonic distortion: Less than 3.0% THD
Output frequency: 60 Hz ± 0.5% crystal controlled
Optional 50 Hz
Operational status LEDs and audible alarm
DC INPUT
Input voltage selection: Nominal 24 VDC
Input voltage tolerance: 20-32 VDC
Input control/protection: 2-pole Guarded DC Circuit Breaker,
Under/Over voltage,
Input Reverse Protection,
Low Voltage Disconnect (LVD) protecting source so vehicle battery does not go below starting voltage
Input power connection: Quick connect (1) NATO Slave female and
Quick connect (1) Anderson Power Pole
Input power cable: Uses standard NATO Slave male-male cable or
Optional 10' Anderson to NATO Slave male connector
DISTRIBUTION PANEL
Output circuits: Four outputs standard
Output protection: GFCI, Ground Fault Circuit Interrupter
Output control: Optional panel switches or breakers
Optional remote interlock ON/OFF control
Output receptacles: NEMA 5-15R straight blade standard
Ground connection: Quick connect jack
MECHANICAL
Enclosure type: Mil Grade casing. Can be fastened to any surface.
Audible noise: <47 dBA @ 5 ft., ANSI "A" scale
Cooling type: Positive pressure fan. thermostatically controlled,
over temperature protection
Air intake filter: Easy clean intake air filter
ENVIRONMENTAL
Storage temperature: -40° to 160° F ambient (-40° to 71° C),
lower/higher optional
Operating temperature: -22° to 140° F ambient (-30° to 60° C )
lower/higher optional
Operating humidity: 0 to 95% relative humidity,
non-condensing, higher optional
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 10,000 ft (3,048 m), higher optional
STANDARDS
United States: Meets UL-1741 and 458
Canada: Meets CSA 107.1 safety requirements
International: Meets EN60950-1 safety requirements
Electromagnetic
Compliance (EMC):
EMI/RFI FCC Part 15, Class B,
EN55022:1997, EN61000-3-2:1998,
EN61000-3-3:1995, EN550204:2001,
e-Mark e13-022025, Others optional
OPTIONAL ACCESSORIES
  Input Cables, Ground Cables w/ Clamp, Ground Rod Kit, Power Distribution Units, Remote Control/Monitor Panel

Request a Quote or Product Info.
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466