ETI0018-1003AA
Portable Universal Mount DC/AC Power Inverter
500 VA, 300
Watts
24 VDC Input
100/ 110/ 120 VAC Output


| AC OUTPUT | |
| Output voltage: | 120 VAC
True sinewave Optional 220 VAC |
| Output rating: | 500 VA, 300 watts continuous |
| Output voltage regulation: | ± 3.0%
static regulation of nominal -10% to +4.0% dynamic |
| Overload surge capacity: | 600 watts surge for 5 seconds |
| Output protection: | Overcurrent protection |
| Harmonic distortion: | Less than 3.0% THD |
| Output frequency: | 60 Hz ± 0.5% crystal
controlled Optional 50 Hz |
| Operational status | LEDs and audible alarm |
| DC INPUT | |
| Input voltage selection: | Nominal 24 VDC |
| Input voltage tolerance: | 20-32 VDC |
| Input control/protection: | 2-pole
Guarded DC Circuit Breaker, Under/Over voltage, Input Reverse Protection, Low Voltage Disconnect (LVD) protecting source so vehicle battery does not go below starting voltage |
| Input power connection: | Quick connect (1) NATO Slave female and Quick connect (1) Anderson Power Pole |
| Input power cable: | Uses standard NATO Slave male-male cable or Optional 10' Anderson to NATO Slave male connector |
| DISTRIBUTION PANEL | |
| Output circuits: | Four outputs standard |
| Output protection: | GFCI, Ground Fault Circuit Interrupter |
| Output control: | Optional panel switches or breakers Optional remote interlock ON/OFF control |
| Output receptacles: | NEMA 5-15R straight blade standard |
| Ground connection: | Quick connect jack |
| MECHANICAL | |
| Enclosure type: | Mil Grade casing. Can be fastened to any surface. |
| Audible noise: | <47 dBA @ 5 ft., ANSI "A" scale |
| Cooling type: | Positive pressure fan.
thermostatically controlled, over temperature protection |
| Air intake filter: | Easy clean intake air filter |
| ENVIRONMENTAL | |
| Storage temperature: | -40° to
160° F ambient (-40° to 71° C), lower/higher optional |
| Operating temperature: | -22° to
140° F ambient (-30° to 60° C
) lower/higher optional |
| Operating humidity: | 0 to 95%
relative humidity, non-condensing, higher optional |
| Storage elevation: | Up to 40,000 ft (12,192 m) |
| Operating elevation: | Up to 10,000 ft (3,048 m), higher optional |
| STANDARDS | |
| United States: | Meets UL-1741 and 458 |
| Canada: | Meets CSA 107.1 safety requirements |
| International: | Meets EN60950-1 safety requirements |
| Electromagnetic Compliance (EMC): |
EMI/RFI
FCC Part 15, Class B, EN55022:1997, EN61000-3-2:1998, EN61000-3-3:1995, EN550204:2001, e-Mark e13-022025, Others optional |
| OPTIONAL ACCESSORIES | |
| Input Cables, Ground Cables w/ Clamp, Ground Rod Kit, Power Distribution Units, Remote Control/Monitor Panel | |