AC
OUTPUT |
Output
voltage: |
120 VAC true sinewave std, 220 VAC optional |
Output
rating: UPS |
500 VA/300 Watt standard,
1000 VA/600 Watt optional
0.60 power factor standard |
Non-linear
load capacity: |
Up to
100% non-linear load capability w/o derating |
Output voltage regulation: |
± 3.0%
static regulation of nominal
± 4.0% dynamic (0 to 50% load step) |
Overload
surge capacity: |
110%
for 10 minutes; 125% for 30 seconds |
Harmonic
distortion: |
Less
than 5.0% into 100% non-linear load |
Output frequency: |
60 Hz ± 1.0%
independent of input frequency, 50 Hz optional |
Operational
status |
Status,
load and battery levels (16) LEDs |
AC
INPUT |
Input
voltage selection: |
Autoranging
from nominal 115 VAC to 230 VAC |
Input voltage tolerance: |
85-264 VAC |
Input
frequency: |
From
47 Hz to 63 Hz |
Input
power factor: |
Better
than 90% typically |
Input/output
isolation: |
3000 VAC, >120 dB common
mode, <1.0 ma leakage |
Input
transient suppression: |
Complies
with IEEE 587 and UL 1449 |
Input
control/protection: |
Guarded circuit breaker, front panel |
Input
power connection: |
AMP CPC, 7 pin, locking |
DC INPUT |
External
DC input: |
Nominal
22 to 32 VDC |
External
DC control/protection: |
Guarded circuit breaker, front panel |
External
DC connector: |
AMP CPC, 7 pin, locking |
INTERNAL BATTERY |
Internal
battery type: |
Maintenance
free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+) |
Internal
battery life: |
Rated
for continuous service life of 5 years |
Internal
battery protection: |
Guarded circuit breaker, front panel |
Internal
battery time: |
10+ minutes
@ 300 watt load, 20+ minutes @ 50% |
Internal
battery recharge: |
Recharged
to nominal in <8 hours |
DISTRIBUTION
PANEL |
Output
circuits:
500 VA UPS
1000 VA UPS |
Two (2) outputs standard,
Six (6) outputs standard,
optional configurations |
Output protection: |
GFCI - Ground Fault
Circuit Interrupter |
Output
receptacles: |
NEMA 5-15R, 3 pin, other options |
MECHANICAL |
Dimensions
( H x D x W ):
500 VA UPS
1000 VA UPS |
3.75 x14.0 x 12.0 in (95
x 356 x 305 mm)
3.75 x14.0 x 12.0 in (95
x 356 x 305 mm) |
Mounting Options: |
Desk, Table,
Wall, Floor, Portable, Horizontal/Vertical |
Unit
weight:
500 VA UPS
1000 VA UPS |
28 lb. (13 kg) with lift
handle front
28 lb. (13 kg) with lift
handles front and rear |
Audible
noise: |
Less
than 47 dB @ 5.0 ft., ANSI "A" scale |
Cooling
type: |
High
capacity, positive pressure, forced air |
Cooling
air direction: |
Rear intake, exhaust to
front |
Air intake
filter: |
Washable
metal filter media, others optional |
ENVIRONMENTAL |
Storage
temperature: |
-13° to
140° F ambient (-25° to 60° C) |
Operating
temperature: |
14° to
122° F ambient ( -10° to 50° C) |
Operating
humidity: |
0 to
95% relative humidity (non-condensing) |
Storage
elevation: |
Up to
40,000 ft (12,192 m), higher optionally |
Operating
elevation: |
Up to
10,000 ft (3,048 m), higher optionally |
STANDARDS |
United
States: |
Meets
UL-1778 standard for UPS equipment,
Meets MIL-STDs 1275, 167-1, 454, 810, 1399-300A &
MIL-S-901 |
Canada: |
CSA C22.2
No. 107 UPS safety requirements |
EMI Protection: |
EMI/RFI FCC, Class A; EN55022 |
OPTIONAL
ACCESSORIES |
|
Emergency
Power Off, Cold Start, Alternate
I/O Configurations, Dual Source Input, Battery
Expansion, Software
Interface, 10BaseT Ethernet SNMP/HTTP port |