P/N: ETI0018-1706
DC/AC Power Inverter
1000 VA, 600 Watts
48 VDC In
Selectable 220*/230/240 VAC Out
FeaturesTrue sinewave output (THD < 3%)
Power On-Off Remote Control
Input & Output fully isolated
Load control cooling fan
Advanced microprocessor
Built-in transfer switch & AC circuit breaker
ROF (Remote Override Function) or ignition lockout function
option
Speed up transfer time & synchronized operation with
utility AC source
Input polarity reverse/ under voltage/ over voltage protections
Output short circuit/ overload/ over temperature protections
Tri-color indicators display input, output level & failure
status
e-13/ CE /FCC approved
Optional 100 /110 /120 VAC Out
Model
Numbers: |
|||
AC Output | |||
AC Voltage |
220 / 230 / 240 VAC | ||
Rated Power |
600 W | ||
Surge Power |
800 W | ||
Waveform |
True sinewave (THD < 3) | ||
Frequency |
50 / 60 Hz selectable by DIP switch | ||
AC Regulation |
+/- 3 | ||
Power Factor
Allowed |
COS -90° ~ COS +90° | ||
Standard Receptacles |
HARDWARE | ||
LED Indicator |
Input voltage level, output load level & fault status | ||
DC
Input |
|||
No Load Current
Draw |
0.83A | 0.43A | 0.22A |
DC Voltage |
12 VDC | 24 VDC | 48 VDC |
Voltage Range |
10.5~15.0 VDC | 21~30 VDC | 42~60 VDC |
Efficiency (Typ.) |
90.0 | 93.0 | 94.0 |
Fuse |
35A x 2 | 15A x 2 | 10A x 2 |
Circuit Breaker |
3 A | ||
Synchronous AC
Transfer |
Yes | ||
Transfer Switch |
10 | ||
Transfer Time |
4~8 msec | ||
Remote Control
Unit |
CR8 optional | ||
Protection |
|||
Low Battery
Alarm |
11 VDC | 22 VDC | 44 VDC |
Low Battery Shutdown |
10.5 VDC | 21.0 VDC | 42.0 VDC |
Over load |
Shut off output voltage, re-power on to recover | ||
Over Voltage |
15.3 VDC | 30.6 VDC | 61.2 VDC |
Over Temperature |
Shut off output voltage, recovers automatically after temperature goes down | ||
Output Short |
Shut off output voltage, re-power on to recover | ||
Battery Polarity |
By fuse opening | ||
Environmental |
|||
Working Temperature |
0 ~ +40° C | ||
Working Humidity |
20 ~ 90 RH non-condensing | ||
Storage Temp.
Humidity |
-30° C ~ +70° C / -22° F ~ +158° F / 10~95 | ||
Standards |
|||
Safety Standards |
|||
Isolation Resistance |
|||
EMI & Radiation |
Compliance to FCC Class A | ||
EMS Immunity |
Compliance to EN61000-3 -2, 3 | ||
LVD |
Compliance to EN60950-1 | ||
e-MARK |
Compliance to e-13 * 72/245/EEC, 95/54/EC | ||
Mechanical |
|||
Dimensions |
393 x 156 x 84 MM (L x W x H) | ||
Packaging |
4.0 kgs; 4 sets / 16 kgs / CARTON | ||
Cooling |
Load controlled cooling fan |