Part Number: ETI0019-2110ED Rugged MilSpec 1000 VATactical Universal Mount DC/AC Power Inverter 500 VA, 300 Watts

Tactical Universal Mount DC/AC Power Inverter
500 VA, 300 Watts
12, 24 or 48 VDC Input


100/ 110/ 120 VAC Output
Optional 220/ 230/ 240 VAC Output

Setup of the Tactical Inverter System is a 'no tools' operation. The unit has been designed for rapid setup and tear down using quick-connect cable terminations. For example to connect to DC power on an HMMWV, Stryker, Abrams or other military vehicle with a NATO Slave connector, simply plug the NATO Slave plug end of the cable into the vehicle's NATO connector and then plug the other end into the corresponding DC Input connector on the Tactical Inverter System. This can be done with an existing NATO Slave cable that some of these vehicle carry; or it can be done with a cable supplied from ETI. In either case, DC setup or tear down is a 2-minute or less operation.

The Inverter draws power from a 12 or 24 VDC source (depending on Tactical Inverter model - see Technical Specifications section) and delivers a Computer-Grade true sine wave AC output voltage that is equal to or better than the voltage supplied by your local utility.  When the DC voltage is within the operating range of the unit, the Inverter will continue to deliver AC power to the loads connected.  If the DC voltage falls out of the specified range of operation, a Low or High DC Shutdown will occur respectively. This feature also protects any battery source from being discharged too low.

Rugged Tactical Inverter

NEMA connectors on Universal Mount Inverter

AC OUTPUT
Output voltage: 120 VAC true sinewave
Optional 220 VAC
Output rating: 500 VA, 300 watts continuous
Output voltage regulation: ± 3.0% static regulation of nominal
-10% to +4.0% dynamic
Overload surge capacity: 600 watts surge for 5 seconds
Output protection: Over current protection
Harmonic distortion: Less than 3.0% THD
Output frequency: 60 Hz ± 0.5% crystal controlled
Optional 50 Hz
Operational status LEDs and audible alarm
DC INPUT
Input voltage selection: Nominal 24 VDC
Input voltage tolerance: 20-32 VDC
Input control/protection: 2-pole Guarded DC Circuit Breaker,
Under/Over voltage,
Input Reverse Protection,
Low Voltage Disconnect (LVD) protecting source so vehicle battery does not go below starting voltage
Input power connection: Quick connect (1) NATO Slave female and
Quick connect (1) Anderson Power Pole
Input power cable: Uses standard NATO Slave male-male cable or
Optional 10' Anderson to NATO Slave male connector
DISTRIBUTION PANEL
Output circuits: Four outputs standard
Output protection: GFCI, Ground Fault Circuit Interrupter
Output control: Optional panel switches or breakers
Optional remote interlock ON/OFF control
Output receptacles: NEMA 5-15R straight blade standard
Ground connection: Quick connect jack
MECHANICAL
Enclosure type: Mil Grade casing. Can be fastened to any surface.
Audible noise: <47 dBA @ 5 ft., ANSI "A" scale
Cooling type: Positive pressure fan. thermostatically controlled,
over temperature protection
Air intake filter: Easy clean intake air filter
ENVIRONMENTAL
Storage temperature: -40° to 160° F ambient (-40° to 71° C),
lower/higher optional
Operating temperature: -25° to 140° F ambient (-32° to 60° C )
lower/higher optional
Operating humidity: 0 to 95% relative humidity,
non-condensing, higher optional
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 10,000 ft (3,048 m), higher optional
STANDARDS
United States: Meets UL-1741 and 458
Canada: Meets CSA 107.1 safety requirements
International: Meets EN60950-1 safety requirements
Electromagnetic
Compliance (EMC):
EMI/RFI FCC Part 15, Class B,
EN55022:1997, EN61000-3-2:1998,
EN61000-3-3:1995, EN550204:2001,
e-Mark e13-022025, Others optional
OPTIONAL ACCESSORIES
  Input Cables, Ground Cables w/ Clamp, Ground Rod Kit, Power Distribution Units, Remote Control/Monitor Panel

Request a Quote or Product Info.
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466