Part Number: ETI0019-2120EE Rugged MilSpec 2000 VA

P/N: ETI0019-2120EE
Tactical Wheeled Carry-On UPS
Rating: 2000 VA, 1500 Watts
Input: 90-264 VAC, 47-63 Hz or
Input: 42-60 VDC
Output: 120 VAC, 50 or 60 Hz


The field proven Tactical Power® UPS line is ideally suited for military, industrial, commercial and telecommunications applications that require a high-quality, high-reliability power source that is rugged in construction yet lightweight, compact and mobile. These units are equally suited for use in the field or aboard vehicles, marine vessels, or aircraft in both controlled or hostile environments. The ETI0019-2120EE is specifically designed for global deployment while delivering up to 2000 VA / 1500 Watts of uninterruptible computer-grade power to critical loads such as computers.

This UPS is built into a heavy-duty case the size of airline carry-on luggage and includes a popup handle and wheels. When the case cover is closed, the unit becomes watertight. The rounded corners and rugged handles aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to mechanical shock and vibration. As a portable UPS, the unit can be used in either a horizontal or vertical position.

View a larger version of one of the small TCW images above
1
1 1 1 1

Designed for both domestic (CONUS) and international (OCONUS) input voltages, this unit's autoranging input voltage selection accepts any AC voltage from 90 to 264 VAC (i.e. nominal 100, 115, 120, 200, 220, 230 or 240 VAC sources) and any frequency from 47 to 63 (i.e. nominal 50 or 60 Hz sources) without special cables or having to open the UPS enclosure. Alternately, the unit also accepts vehicular or aircraft power from nominal 48 VDC systems. This allows the unit to be operated when no AC source is available. Optional 12 VDC and 24 VDC versions are also available.

The high-reliability LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. For situations requiring more stealth, the LEDs can be dimmed or extinguished and the audible feature disabled. All controls and protective devices are brought to front panel with critical controls having finger guards to prevent damage or accidental operation. 

The ETI0019-2120EE has the added benefit of having a field replaceable battery via front drawout battery module. Even if this battery module removed or depleted, this UPS can continue to operate as an electronic power conditioner and frequency converter, providing clean, well regulated, sinusoidal power to the load. The VRLA AGM batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials for added safety. For more information, see the Battery Technology section.schematic

A removable and washable intake air filter and high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments.

Maintaining documentation for equipment in the field has always been an issue. Instead of having to carry bulky paper documentation, the ETI0019-2120EE incorporates the eDocs Port™, a patented feature unique to Energy Technologies, Inc. This flash drive contains all the relevant documentation for the unit at hand. This includes Operation and Maintenance manuals as well as training and troubleshooting guides. Utilizing a standard USB interface, these standardized electronic documents are readily available to the user.

Overall, the Tactical Power line is uniquely qualified for critical vehicle, airborne, shipboard, or land based systems combining advanced modular design features with highly reliable construction.


Portable Global Input 1000 VA UPS
P/N: ETI0019-2120EE
AC OUTPUT
Output voltage (standard): 120 VAC true sinewave output standard setting
100 or 110 VAC optional settings available
Output voltage (optional): 220, 230 or 240 VAC version available, see ETI0019-2120EF
Output rating (standard): 2000 VA, 1500 Watts standard
Output rating (optional): 1000 VA, 700 watts version available, see ETI0019-2110EE
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: ± 3.0% static regulation of nominal
± 5.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: 60 Hz or 50 Hz switch selectable
Operational status: AC Input status, UPS operational, Battery level, Low battery,
Load level, Overload LEDs, audible alarm w/audible on/off switch
AC INPUT
Input voltage (AC Input): Autoranging from nominal 90 VAC to 264 VAC
Input frequency: From 47 Hz to 63 Hz standard, optional up to 440 Hz
Input power factor: Better than 95% typically
Input/output isolation: up to 120 dB common mode, <2.0 ma leakage
Input transient suppression: Complies with IEEE 587, UL 1449 and Mil Std 1399
Input control/protection: Guarded circuit breaker
Input power connections: One IEC 60320-C20 male, 3 pin with cable restraint
Input power cable: One 6' cord w/IEC 60320-C19 female and NEMA 5-15P
Input power cable adapters: One kit of universal plug adapters for most global outlets
DC INPUT / INTERNAL BATTERY
External DC input (standard): 48 VDC Nominal 42 to 60 VDC
External DC input (optional): 12 VDC Nominal 10.5 to 15 VDC version available, see ETI0019-2120EB
External DC input (optional): 24 VDC Nominal 21 to 30 VDC version available, see ETI0019-2120EA
External DC control/protection: Thermal circuit breaker
External DC connector: CPC, 7 pin, locking
Internal battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal battery life: Rated for continuous service life of 5 years
Internal battery time: 5+ minutes @ 750 watt load, 15+ minutes @ 375 watt load
Internal battery recharge: Recharged to nominal in <8 hours
Internal battery replacement: Drawout/plug-in module from front of unit
<5 minutes to change battery modules
Battery expansion: Up to 24 hours w/ optional Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Four AC outputs standard, several optional configurations
Output protection (standard): One GFCI (Ground Fault Circuit Interrupter) duplex, one standard duplex
Output protection (optional): Individual push/pull circuit breakers available for each outlet
Output receptacles: AC output  NEMA 5-15R with dust covers, others optional
MECHANICAL
Dimensions (H x D x W): 21.75 x 8.99 x 13.75 in (552 x 228 x 349 mm)
Unit weight:
      UPS and Battery
      UPS only
      Battery Module only

50 lb. (23 kg) with lift handles front and rear
24 lb. (11 kg) with lift handles front and rear
26 lb. (12 kg) with lift handle in front
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Air intake filter: Washable filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C)
Operating temperature: 32° to 126° F ambient ( 0° to 52° C), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 50,000 ft (15,240 m), higher optional
Operating elevation: Up to 10,000 ft (3,048 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
Meets MIL-STDs 1275, 167-1, 454, 810, 1399-300A & MIL-S-901
Canada: Meets CSA C22.2 No. 107 UPS safety requirements
EMI Protection: Meets EMI/RFI FCC Part 15, Class A; EN55022
OPTIONAL ACCESSORIES
  Cold Start, Alternate I/O Configurations, Battery Expansion,
Battery Charger/Conditioner, Power Distribution Units

Request a Quote or Product Info.
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466